4-20ma Natural Gas Steam Liquid Integrated Porous Orifice Plate Balance Flow meter

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Accurate orifice plate flow meter For Precise Measurements ...

    Get Price
  • integrated flow meter, integrated flow meter Suppliers and ...

    4-20ma Natural Gas Steam Liquid Integrated Porous Orifice Plate Balance Flow Meter. US 170.00 Piece. 1 Piece (Min. Order) CN Chengdu Sentec Technology Co., Ltd. 3 YRS. 90.0%. 4.8 (18) 'Good supplier' 'Good packaging' Contact Supplier. 1/5. 2019 Custom integral type water insertion flow meter,electromagnetic beer flowmeter,liquid nitrogen ...

    Get Price
  • orifice plate flow, orifice plate flow Suppliers and ...

    Alibaba.com offers 1,237 orifice plate flow products. About 19% of these are Flow Meters, 0% are Valves. A wide variety of orifice plate flow options are available to you, such as structure, application, and warranty.

    Get Price
  • integrated orifice flow meter, integrated orifice flow ...

    Alibaba.com offers 1,617 integrated orifice flow meter products. A wide variety of integrated orifice flow meter options are available to you, such as type, customized support.

    Get Price
  • orifice plate flow meter liquid, orifice plate flow meter ...

    Alibaba.com offers 924 orifice plate flow meter liquid products. A wide variety of orifice plate flow meter liquid options are available to you,

    Get Price
  • Orifice flowmeter installation guidelines

    Orifice flowmeter installation guidelines. The orifice flowmeter is a high-range differential pressure flow device,that combines a standard orifice plate with a multi-parameter differential pressure transmitter (or differential pressure transmission, temperature transmitter and pressure transmitter) to measure gas and steam , liquid and natural gas flow.

    Get Price
  • Orifice plate flow meter - Omega Engineering

    2019-4-17 · The orifice plate flow meter is commonly used in clean liquid, gas, and steam services. It is available for all pipe sizes but it is very cost-effective for measuring flows in larger ones (over 6' diameter). The orifice plate is also approved by many organizations for custody transfer of liquids and gases. The orifice plate calculations used ...

    Get Price
  • Manual: Rosemount Integral Orifice Flowmeter Series

    2019-8-7 · Rosemount ™ Integral Orifice Flow Meter Series. The sections in this manual are organized as follows: ... and shall be measured from the upstream face of orifice plate. 0.20 20 24 25 30 22 22 10 0.40 25 27 31 ... Rosemount 1195 should not be used in vertical liquid or steam applications if the fluid is flowing down. Vertical steam should be ...

    Get Price
  • Rosemount 3051SFP Integral Orifice Flow Meter

    The Rosemount 3051SFP Integral Orifice Flow Meter is a no-equal multivariable device customized with an integral orifice primary element. This meter run assembly provides easy installation and is engineered to facilitate highly accurate flow measurement in small line sizes (0.5 - 1.5 in. or 15 - …

    Get Price
  • Differential Pressure Fuel Liquid Gas Orifice Plate Flow ...

    Description of differential pressure fuel orifice plate liquid gas flow meter: Orifice flowmeter is a high range specific differential pressure flow device which is composed of standard orifice plate and multi-parameter differential pressure transmitter (or differential pressure , temperature and pressure transmitter).It has simple structure, convenient maintenance and stable performance.

    Get Price
  • Manual: Rosemount Integral Orifice Flowmeter Series

    2019-8-7 · Rosemount ™ Integral Orifice Flow Meter Series. The sections in this manual are organized as follows: ... and shall be measured from the upstream face of orifice plate. 0.20 20 24 25 30 22 22 10 0.40 25 27 31 ... Rosemount 1195 should not be used in vertical liquid or steam applications if the fluid is flowing down. Vertical steam should be ...

    Get Price
  • Types of Steam Flowmeter

    Disadvantages of orifice plate steam flowmeters: Turndown is limited to between 4:1 and 5:1 because of the square root relationship between flow and pressure drop. The orifice plate can buckle due to waterhammer and can block in a system that is poorly designed or installed.

    Get Price
  • eYc FOM09 Porous Orifice Plate Balanced Flowmeter

    eYc FOM09 Porous Orifice Plate Balanced Flowmeter. FOM09 Balance the flowmeter can maximize the rectifier into ideal fluid flow field in balance, to measure the differential value according to the Bernoulli equation to calculate the flow in the pipeline. Balance disc throttling of flow sensor is a porous …

    Get Price
  • Rosemount 3051SFC Compact Conditioning Orifice Plate Flow ...

    The Rosemount 3051SFC Compact Conditioning Orifice Plate Flow Meter is a no-equal solution for multivariable measurement, obtaining direct variable measurements in combinations of differential pressure, static pressure and process temperature. This flow meter comes with a patented, 4-hole conditioning orifice plate for accurate measurement in ...

    Get Price
  • WLG Orifice Plate Meter, MGG/Z Rota Meter, LUGB Vortex ...

    2019-11-13 · DN65 Caliber Waste Water Mechanical Acid Liquid Flow Meter. Inquire Now. Water Milk Analog Magnetic Flow Meter Price Electromagnetic Flowmeter ... Digital natural Gas Vortex Flowmeter ... Inquire Now. Measured Range 4-20 Liquid Level Gauge Transmitter. Inquire Now. High Precision Ss304 4-20ma Gas Orifice Plate. Inquire Now. Sea river measuring ...

    Get Price
  • Rosemount 3051SFC Compact Conditioning Orifice Plate Flow ...

    Close. Back. Brands; Back. Featured Brands; Fisher Control Valves Bettis Actuators

    Get Price
  • Gas Flow Orifice Calculator

    2021-8-16 · Download our mobile calculator app on the Google Play Store. Our flow products and custom components are measured in three different tiers: Standard Components. All standard orifice components are optically measured on instruments that are calibrated with Lenox Laser traceable bar chart standards.

    Get Price
  • Rosemount 3051SFC Compact Orifice Plate Flow Meter

    Built with a compact orifice plate, this flow meter provides measurements for closed loop control, general purpose monitoring and custody transfer applications. Available in line sizes up to 12 in. (300 mm), this primary element is designed for gas, liquid and steam service and operates well in harsh process conditions.

    Get Price
  • Epsi-Steem Flowmeter for Steam - DP-Flow Ltd

    2021-6-21 · EPSI-STEEM ES1; ES2. The EMCO EPSI-STEEM compact orifice flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical and the power industry. The EPSISTEEM is especially designed for installations with limited space due to the flow conditioning effect created by the 5 hole design.

    Get Price
  • Standard Orifice Flowmeter

    Porous Bronze Plates (BK) Porous Bronze Discs (BC) Stainless Steel. Porous Stainless Steel Multi Cartridges (CFI) ... natural gas,saturated vapor, superheated steam, other mixed gas or liquid: Medium Temperature: _10°C~+450°C: Power supply: Smart flow display 220VAC, Flow transmitter24VDC: Output signal: 4-20mA …

    Get Price
  • eYc FOM09 Porous Orifice Plate Balanced Flowmeter

    eYc FOM09 Porous Orifice Plate Balanced Flowmeter. FOM09 Balance the flowmeter can maximize the rectifier into ideal fluid flow field in balance, to measure the differential value according to the Bernoulli equation to calculate the flow in the pipeline. Balance disc throttling of flow sensor is a porous …

    Get Price
  • Datasheet Orifice plate – multi-holes

    ISO5167 standard The multi-holes orifice plate is a non-standardized flow element but is designed and manufactured according to ISO5167 standard requirements. The sizing of multi-holes orifice plates is achieved in our design office with the same software as the one used for sharp-edge orifice plates in compliance with the ISO5167 standard.

    Get Price
  • Restriction Orifice Plates and Critical Flow Devices

    2021-8-15 · Flow measurement of liquid, gas and steam according to the differential pressure principle has been recognised principle for very many years using orifice plates, venturi tubes and flow nozzles. A restriction in the pipe line creates a …

    Get Price
  • Rosemount 3051SFC Compact Orifice Plate Flow Meter

    test; 24/7 After Hours Support 1-(518)-292-0356; News; Resources; Emerson Impact Partner Network; Careers; New Customers; Customer Feedback; Contact Us Portal Sign In

    Get Price
  • Rosemount 3051SFC Compact Conditioning Orifice Plate Flow ...

    Facebook; Linked in; Twitter; 24/7 After Hours Support 1-877-827-8131; Brands; Contact Us; About Us; Careers; News RCC Login; Customer Survey

    Get Price
  • Primary element flowmeter for gas, steam and liquid

    2021-8-15 · Primary element for flow measurement with gas, steam and liquid Differential pressure flow measurement is oneof the most widely used measurement principles in the industry. The main field of application is the measurement of water in heating and cooling circuits and the measurement of steam and condensates at very high temperatures in secondary circuits.

    Get Price
  • digitalYEWFLO Vortex Flow Meter

    The digital YEWFLO vortex flow meter combines the field proven sensor and body assembly used in more than 450,000 units installed worldwide with a unique and powerful combination of digital technology that includes spectral signal processing (SSP), a Yokogawa innovation.The digitalYEWFLO vortex flow meter …

    Get Price
  • How to install an Orifice Plate? Installation Guidelines

    2021-8-13 · 1.Installing an Orifice Meter. The section of the pipe in which the primary element is installed can be horizontal, inclined or vertical. Orifice Plate Installation Guidelines. The direction of the flow is immaterial except when a foreign substance such as sediment or vapor is carried in suspension. Orifice Plate Installation Detail.

    Get Price
  • Nivå och Flödesutrustning - Digiflow 515

    2019-4-18 · Nivå och Flödesutrustning - Digiflow 515 (Microprocessor Gas and Steam Flow Computer -Consumption and Enthalpy for Steam) Product Functions • Indication of Flow Rate and Total of Volume, Mass and Energy. • Temperature and Pressure Compensation. • Input Signals 4-20 mA analog or frequency for flow input. • Dual Ranged D.P. Transmitter Inputs • Simplified …

    Get Price
  • How a Orifice Measures Flow ? - InstrumentationTools

    2021-8-9 · An Orifice Meter is basically a type of flow meter used to measure the rate of flow of Liquid or Gas, especially Steam, using the Differential Pressure Measurement principle. It is mainly used for robust applications as it is known for its durability and is very economical. As the name implies, it consists of an Orifice Plate …

    Get Price
  • Flow measuring technology For liquids, gases and steam

    2016-8-22 · Flow is one of the most frequently measured process variables in industry. Water, natural gas, steam, mineral oil, chemicals or wastewater are only some examples of fluids

    Get Price
  • Rosemount 3051SFC Compact Conditioning Orifice Plate Flow ...

    Facebook; LinkedIn; 24/7 After Hours Support (206) 236-3117; Careers; News Portal; About Us; Products; Services; Industries; Training; Brands

    Get Price
  • Rosemount 3051SFC Compact Conditioning Orifice Plate Flow ...

    Facebook; LinkedIn; Twitter; YouTube; 24/7 Support 610.495.1835; Resources; Pros At Proconex; Careers Customer Portal; Products; Brands; Services

    Get Price
  • EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS

    2004-6-29 · EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS William Johansen Colorado Engineering Experiment Station, Inc. 54043 WCR 37, Nunn, Colorado 80648 INTRODUCTION Natural gas often has some liquid content. The liquid may be water, hydrocarbons, or compressor oil. As this gas flows through an orifice meter is the gas being measured correctly?

    Get Price
  • Epsi-Steem Flowmeter for Steam - DP-Flow Ltd

    2021-6-21 · EPSI-STEEM ES1; ES2. The EMCO EPSI-STEEM compact orifice flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical and the power industry. The EPSISTEEM is especially designed for installations with limited space due to the flow conditioning effect created by the 5 hole design.

    Get Price
  • Fundamentals of Orifice Metering - American School of Gas ...

    2015-3-2 · plate carrier, rubber seals for the orifice plate (assures no by-pass of the liquid or gas around the plate), a sealing bar, and a clamping bar. One such design is shown in Figure 4. The orifice plate is held in the carrier by means of a seal ring. The carrier is attached to the sealing bar and can be removed from the body as one assembly, once

    Get Price
  • 4 Natural Gas Flow Meter Types for Gas Measurement

    2021-1-12 · Natural Gas Flow Meter Types. There are four natural gas meter types often used for flow measurement. They are mass flow meters, velocity flow meters, differential pressure, and PD meters. What is a flow meter? A flow meter is a precision instrument that measures gas flow rate (or liquid flow…

    Get Price
  • Flow Measurement

    2021-8-16 · Armstrong Ultrasonic Flowmeter and BTU Meter. The Armstrong Ultrasonic Flowmeter (AUF) is designed to be installed at a fixed location for long-term flow measurement on a closed pipe, carrying pure liquids or liquids with …

    Get Price
  • Orifice Plate Calculator - Find Size - FREE Online ...

    2021-8-6 · Beta Ratio is the ratio between the line inner diameter to bore size of the orifice. The flow coefficient is found to be stable between beta ratio of 0.2 to 0.7 below which the uncertainty in flow measurement increases. An orifice plate beta ratio of 0.6 means that the orifice plate bore diameter is 60% of the pipe internal diameter.

    Get Price
  • Mass flow rate measurements in gas–liquid flows by means ...

    2009-1-1 · Two-phase flow correlations were tested, and the experimental quality and slip ratio factor were analyzed. A comparison between the performance of an orifice plate and a venturi in gas–liquid flow was carried out. 2. Literature reviewAdiabatic steady-state two-phase flow fundamentals are reviewed in this section.

    Get Price
  • Flow Meter, Orifice Flowmeter,Water Meter, Gas Meter ...

    2021-8-11 · Separate Type Electromagnetic Flow Meter. Glass Tube Rotameter Gas Flow Meter. Emerson Rosemount 3051 Pressure Transmitter. Industrial Digital Pressure Gauge with 4-20mA. Yokogawa Gauge Pressure Transmitter. Emerson 475 Hart Field Communicator. Mechanical Oval Gear Flow Meter. Flange Mounted Liquid Level Transmitter. PT100 Thermocouple RTD Sensor

    Get Price
  • EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS

    2003-1-20 · EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS William Johansen Colorado Engineering Experiment Station, Inc. 54043 WCR 37, Nunn, Colorado 80648 INTRODUCTION Natural gas often has some liquid content. The liquid may be water, hydrocarbons, or compressor oil. As the gas flows through an orifice meter is the gas being measured correctly?

    Get Price
  • Calculator: Steam Flow Rate through an Orifice

    2020-1-30 · Online calculator to quickly determine Steam Flow Rate through an Orifice. Includes 53 different calculations. Equations displayed for easy reference.

    Get Price
  • ISA 1932 Flow Nozzle

    The ISA 1932 flow nozzle is generally used for the measurement of liquid or gas flows including steam, erosive, high-velocity and non-viscous media. They do not rely on a sharp edge (which can deteriorate over time) to maintain accuracy and therefore …

    Get Price
  • Types of Orifice Plates Used in Flow Measurement

    2018-8-23 · Orifice plates are one of the most popular devices for the measurement and control of fluid flow. It is frequently used more than any other flow meter. The orifice consists of a thin metal plate with a straight hole drilled in it. When a fluid passes through an orifice, the flow …

    Get Price
  • Large Diameter Orifice Flow Meter Calculation for Gas Flow

    2017-4-17 · Large Diameter Gas Orifice Flow Meter. Computes for Gas flow - flowrate, orifice diameter or differential pressure for pipe diameter greater than 50 mm based on ISO-5167 standards. Result.

    Get Price
  • Notes on the orifice meter: The expansion factor for gases

    2012-7-31 · orificeforwhich=0.1241indicatedthatacurve,slightlyconvex upward,would be a little better than astraight fine, aresultin accord- ancewithotherobservations on orifices of diameter ratios belowabout

    Get Price
  • Basics of Flow Measurement with the Orifice Flow Meter I ...

    2021-3-6 · Both liquid and gas density change with temperature as a result, they are compensated for in a differential pressure flow measurement system like the orifice plate flow meter. Flow Measurement Setup The complete flow measurement installation of an orifice flow meter …

    Get Price
  • Industrial Flow Meters & Rotameters

    From inline to low volume flow meters Brooks offers high-performance gas and water flow measurement instruments for your application. This broad portfolio includes armored metal, glass tube and plastic VA flow meters (rotameters), each engineered to provide years of repeatable, reliable measurement of gas and liquid flow …

    Get Price
  • AGA 3 Gas Flow Equation for Orifice Plates ~ Learning ...

    2021-3-6 · Recall that we have discussed the ISO 5167 Orifice Meter Equation.While some companies use the ISO 5167 orifice gas flow equation, a vast majority of companies use the American Gas Association committee report 3 gas flow equation otherwise referred to as AGA 3 Gas Flow Equation for Orifice Plates.

    Get Price
  • Restriction Orifice Plate Rev01.ppt

    2016-3-7 · Restriction Orifice Plate Program Cont’d This is one of the best stand alone Restriction Orifice Plate program available. 1. Liquid and gas, steam or vapor flow options. 2. Multiple units of measure choices -mass or volume 3. Physical properties based on chosen temperature and pressure 4. Element and pipe material selection 5.

    Get Price
  • EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS

    2004-6-29 · EFFECTS OF ENTRAINED LIQUID ON ORIFICE MEASUREMENTS William Johansen Colorado Engineering Experiment Station, Inc. 54043 WCR 37, Nunn, Colorado 80648 INTRODUCTION Natural gas often has some liquid content. The liquid may be water, hydrocarbons, or compressor oil. As this gas flows through an orifice meter is the gas being measured correctly?

    Get Price
  • Notes on the orifice meter: The expansion factor for gases

    2012-7-31 · orificeforwhich=0.1241indicatedthatacurve,slightlyconvex upward,would be a little better than astraight fine, aresultin accord- ancewithotherobservations on orifices of diameter ratios belowabout

    Get Price
  • Calculator: Water Flow Rate through an Orifice

    2020-1-30 · Online calculator to quickly determine Water Flow Rate through an Orifice. Includes 53 different calculations. Equations displayed for easy reference.

    Get Price
  • Orifice plate - Flow meter Directory

    2017-9-25 · Orifice plates are widely used for flow measurement as they provide the simplest and the most economical means of flow detection. Orifice plates are available in the concentric type that the round opening (Bore) of the orifice plate is positioned concentrically with the center of the pipe and the opening edge (Bore edge) is available either in the concentric square edge type (Sharp, …

    Get Price
  • Orifice plate flowrate calculation : formula and calculator

    2021-7-19 · q m = flow rate of the fluid through the orifice (kg/s) C = coefficient of discharge (often 0.65 for an orifice plate) β = d/D ε = expansibility factor (for gas only, for liquid epsilon = 1) D = pipe diameter (m) d = orifice diameter (m) ρ = fluid density upstream the orifice plate (kg/m3) ΔP = pressure drop through the orifice plate (Pa)

    Get Price
  • Small Bore Orifice Flow Meter Calculation for Gas Flow

    Orifice flow meters are used to determine a liquid or gas flow rate by measuring the differential pressure P 1-P 2 across the orifice plate. Orifice flow meters are generally less expensive to install and manufacture than the other commonly used differential pressure flow meters; however, nozzle and venturi flow …

    Get Price
  • Small-Bore Gas Orifice Meter Flow Calculator

    2021-8-10 · Small-Bore Gas Orifice Meter Flow Calculator. This Excel spreadsheet calculates the flowrate from a small-bore gas orifice meter using the ASME MFC-14M-2001 standard. This calculator is valid for pipe diameters of less than 40 mm (other restrictions are given below). The equations are as follows. C is the discharge coefficient.

    Get Price
  • Venturi Flow meter

    2017-9-25 · The CV Venturi Flow Meter is a differential pressure element de signed to accurately measure the flow of liquids and gases by forcing the flow into a smaller diameter section of pipe, then measuring the pressure differences between the unrestricted flow and the restricted flow.

    Get Price
  • Rosemount 3051SFC Compact Annubar Flow Meter

    Facebook; LinkedIn; COVID-19 Response; Emergency Support and Service 888­-268-6437; Careers; Resources; News; Company Store Customer Portal

    Get Price
  • Orifice Plates for Flow Measurement and Flow Restriction

    2020-6-1 · Paddle Orifice Plates are used with raised-face orifice flanges for measurement applications and installed between standard ASME flanges for restriction applications. The plate and handle are a one-piece seamless design on 1/8-in. thick orifice plates …

    Get Price
  • Gas Flow Meters & Mass Controllers

    Gas Flow Meters & Mass Controllers Accurate Mass Flow Measurement. Sierra designs and manufactures a wide range of today's most advanced analog and digital gas flow meters, mass flow meters, mass controllers and switches across three core technologies: Capillary Thermal, Immersible Thermal, and Mass Vortex.Each gas flowmeter or gas controller meets exacting …

    Get Price
  • 7 technologies for steam flow measurement

    2010-9-26 · Steam flow measurement accounts for about 6 percent of the revenues from flowmeters sold in today’s 4.5 billion flowmeter market. While as many as seven different types of flowmeters can be used to measure steam flow, the vast majority of steam flow measurements are made with differential-pressure (DP) and vortex flowmeters.

    Get Price
  • Orifice Flow Meter Calculators

    2021-8-10 · Large Bore Gas Orifice Meter (ISO 5167) Small Bore Liquid Orifice Flow Meter Calculator (ASME MFC-14M-2001) Small Bore Gas Orifice Flow Meter Calculator (ASME MFC-14M-2001) Email This BlogThis! Share to Twitter Share to Facebook Share to Pinterest. 0 comments: Post a Comment.

    Get Price
  • Orifice plate flowrate calculation : formula and calculator

    2021-7-19 · q m = flow rate of the fluid through the orifice (kg/s) C = coefficient of discharge (often 0.65 for an orifice plate) β = d/D ε = expansibility factor (for gas only, for liquid epsilon = 1) D = pipe diameter (m) d = orifice diameter (m) ρ = fluid density upstream the orifice plate (kg/m3) ΔP = pressure drop through the orifice plate (Pa)

    Get Price
  • Orifice Flow Meter » The Piping Engineering World

    2021-8-16 · Process Instrumentation Flow Measurement This is the most common type of flow meter used in process industry. It consists of an orifice plate with a pair of orifice flanges, which are tapped to receive sensing connections. Complete assembly consists of an orifice plate, orifice …

    Get Price
  • Coastal Flow

    Coastal Flow is an independent gas and liquid measurement company headquartered in Houston, Texas. We provide measurement and analytical services throughout the United States and abroad. Our customers include oil and gas producers, gatherers, processors, pipelines, refineries, and petrochemical companies. Click links below to read more about ...

    Get Price
  • Solutions manual for White Fluid Mechanics 5th Edition ...

    1.76 Estimate the speed of sound of steam at 200°C and 400 kPa, (a) by an ideal-gas approximation (Table A.4); and (b) using EES (or the Steam Tables) and making small isentropic changes in pressure and density and approximating Eq. (1.38). Chapter 1 • Introduction 41 Solution: (a) For steam, k 1.33 and R = 461 m2/s2·K.

    Get Price
  • L&T REPORT - SlideShare

    2017-2-2 · Magnetic flow meters 4. Turbine meters 5. Target meter 6. Vortex flow meters, 7. Ultrasonic flow meters 5.5.1.1 Variable head or differential flow meters Orifice plate The simplest and the most common pipeline restriction used in DP method of flow measurement is the Orifice Plate, which is a thin, circular metal plate …

    Get Price