soda phosphoric Formic organic fuming nitric hydrofluoric acid aqua regia electromagnetic flowmeter

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • ip65 electromagnetic flowmeter manufacturers, ip65 ...

    Alibaba.com offers 1,939 ip65 electromagnetic flowmeter manufacturers products. A wide variety of ip65 electromagnetic flowmeter manufacturers options are available to you, such as certification, warranty, and type.

    Get Price
  • weili 4-20mA output Electromagnetic Flowmeter For Sewage ...

    weili 4-20mA output Electromagnetic Flowmeter For Sewage Flow Meter, US 265 - 325 Set, 3 years, OEM, Henan, China.Source from Henan Weili International Trading Co., Ltd. on Alibaba.com.

    Get Price
  • Electromagnetic flowmeter in the proper selection of material

    Resistance to boiling hydrochloric acid, sulfuric acid, nitric acid and aqua regia, strong alkali and a variety of organic solvents, good wear-resisting function, poor adhesion function. Above is the electromagnetic flowmeter, the choice of material of different medium has different characteristics, don't have to choose the most expensive ...

    Get Price
  • Wastewater Flowmeter Liquid Caustic Soda Electromagnetic ...

    Wastewater Flowmeter Liquid Caustic Soda Electromagnetic Flow Meter , Find Complete Details about Wastewater Flowmeter Liquid Caustic Soda Electromagnetic Flow Meter,Liquid Caustic Soda Flow Meter,Wastewater Flowmeter,Wastewater Flowmeter Naoh Liquid Caustic Soda Flow Meter from Flow Meters Supplier or Manufacturer-Henan Junyuan Automation Equipment Co., Ltd.

    Get Price
  • SHmeters - Electromagnetic Flowmeter Manufacturer Supplier ...

    1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions 2. Strong abrasion resistance and poor bonding performance 3. There must be no negative pressure in the pipeline: Perchloroethylene propylene F-46(PTFE) 1.

    Get Price
  • 220v sewage digital electromagnetic flowmeter with display ...

    Application: concentrated hydrochloric acid, nitric acid, sulfuric acid and other acid liquids, including boiling hydrochloric acid and nitric acid. PH value: within 3/4/5/6. Not applicable: alkali, hydrofluoric acid, fuming sulfuric acid. Pt. Various acids, bases, salts. Not included: Royal Water

    Get Price
  • Model LDBE Electromagnetic Flowmeter - Strong M&C

    Model LDBE intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company with the most advanced technology. It is very different from the old analog or non-intelligent electromagnetic flowmeter…

    Get Price
  • BFM Series Electromagnetic Flowmeter General E=kBDV ...

    boiling phosphoric acid, formic acid, aqueous alkali, and sulfurous acid, sea water, and acetic acid in a certain amount of pressure. seawater and brine For no eroding but high wear and tear liquid Seawater, various chlorid and hypochlorite, gasified acid (including fuming nitric acid), organic acid, and alkali.

    Get Price
  • Wholesale Ortho-phosphoric Acid H3po4 Flowmeter Flowmeter ...

    Ortho-phosphoric Acid H3po4 Flowmeter Flowmeter . Note: Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order. Trade Assurance. Built-in order protection service in alibaba.com.

    Get Price
  • How To Choose The Correct Sulphuric Acid Electromagnetic ...

    4. The remaining chemical media other than fuming sulfuric acid and alkali, including boiling point hydrochloric acid, nitric acid and <175 ° C sulfuric acid can be used. 5. Platinum. Can be used in a variety of acids, bases, salts, but does not include aqua regia.

    Get Price
  • Electromagnetic Flowmeter - SH Flow Tech

    Capable of measuring domestic sewage, non-corrosive industrial sewage PH value: in the range of 6/7/8, temperature below 80 ℃ liquid. 3. There must be no negative pressure in the pipeline. 1. Boiling-resistant hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali and various organic solutions.

    Get Price
  • battery powered flange connection electromagnetic flowmeter

    1.Hydrochloric acid (concentration is less than 40%), dilute sulphuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid). 2.Chlorine dioxide, ferric chloride, hypochlorite, sodium cyanide, lead acetate, etc. 3.Nitric acid (including fuming nitric acid) and other oxidizing acids, the temperature below 80 degrees of aqua regia.

    Get Price
  • Model LDBE Electromagnetic Flowmeter - Strong M&C

    Model LDBE intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company with the most advanced technology. It is very different from the old analog or non-intelligent electromagnetic flowmeter…

    Get Price
  • Source Water Electromagnetic Flowmeter Price on m.alibaba.com

    Water Electromagnetic Flowmeter Price, You can get more details about from mobile site on m.alibaba.com. 199.00 - 1,999.00 . Min. Order : 1 Piece Water Electromagnetic Flowmeter Price . Get Latest Price Trade Assurance. Built-in order protection service in alibaba.com.

    Get Price
  • BFM Series Electromagnetic Flowmeter General E=kBDV ...

    boiling phosphoric acid, formic acid, aqueous alkali, and sulfurous acid, sea water, and acetic acid in a certain amount of pressure. seawater and brine For no eroding but high wear and tear liquid Seawater, various chlorid and hypochlorite, gasified acid (including fuming nitric acid), organic acid, and alkali.

    Get Price
  • Electromagnetic Flowmeter MX-LL-116-01_Shanghai MX-CEKONG ...

    MX - LL - 116-01 series Electromagnetic flowmeter (Electromagnetic Flowmeters, EMF) : according to Faraday's law of Electromagnetic induction (Faraday's law of Electromagnetic induction: when the conductor in magnetic field cutting lines of magnetic force exercise, on both ends of a conductor will be induced a conductor and magnetic field direction and movement direction perpendicular induced ...

    Get Price
  • Electromagnetic flow meter no pressure loss measuring ...

    electromagnetic flowmeter measurement principle is Faraday's law of electromagnetic induction, the main components of the sensor are: measuring tube, electrode, excitation coil, core and yoke shell. Electromagnetic flowmeter is mainly used to measure the volume flow in the conductive liquid and slurry in the closed pipe. Including acid…

    Get Price
  • Magnetic Flow Meter - Switches and Sensors for Sale

    boiling phosphoric acid, formic acid. aqueous alkali. and sulfurous acid. sea water. and acetic acid in a certain amount of prcssurc. seawater and brine Carbonized Tungsten For no eroding but high Wcarand tear liquid Tantalum Seawater, various chlorid and hypochlorite, gasified acid (including fuming nitric acid), organic acid, and alkali.

    Get Price
  • How to select the material electromagnetic flow meter ...

    As a common flow measurement, it is a key factor to select the materials of electromagnetic flow meter, because only internal electrode and the measuring tube in contact with the media, therefore, according to the characteristics of different media, you need to select the correct electrode and lining materials.. Electrode materials:. Stainless steel (0Cr18Ni12Mo2Ti).

    Get Price
  • DN2000 Beverage Sanitary Electromagnetic Flow Meter

    Liner Material: Main Performance: Application: PTFE: 1 The most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong bases and various organic solvents, but not resistant to the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    Get Price
  • Electromagnetic flowmeter material selection guide- strong ...

    Electromagnetic flowmeter material selection guide- strong corrosion of the series. Electromagnetic flowmeter in the industry though often used to measure medium water, but the greatest advantages of electromagnetic is measured as long as the conductive liquid medium, it can satisfy the measurement requirements, and the application of measuring accuracy is higher than other meter, so when the ...

    Get Price
  • Carbon steel electromagnetic flowmeter - Supmea Automation

    Supmea Magnetic flowmeter operate under the principle of Faraday's Law of Electromagnetic Induction to measure liquid velocity. Following Faraday's Law, magnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. In order of usage, magnetic flowmeter …

    Get Price
  • FLEM Electromagnetic Remote Flowmeter

    FLEM Electromagnetic Remote Flowmeter measure liquid velocity. It can be used in inductive liquids in pipes, such as water, acids, caustic, and slurries. It is used in water/wastewater industry, chemical, food and beverage, power, pulp and paper, metals and mining, and pharmaceutical application.

    Get Price
  • Electromagnetic flowmeter--Changzhou Yueheng Instrument ...

    Electromagnetic flowmeter: Brief Type LD Electromagnetic flowmeter is based on Faraday's law of electromagnetic induction, using the most advanced technology research and development of all intelligent instruments, its wholly Chinese high-speed electromagnetic transducer core central processor, computer speed, high precision measurement and reliable performance.Magnetic stability, special ...

    Get Price
  • How To Choose The Material Of Electromagnetic Flowmeter ...

    4. Tantalum.In addition to hydrofluoric acid, fuming sulfuric acid, alkali other chemical media, including boiling point hydrochloric acid, nitric acid and < 175℃ sulfuric acid can be used. 5. Platinum.Can be used for all kinds of acid, alkali, salt, but does not include aqua regia.

    Get Price
  • Anticorrosion Measures And Methods For Electromagnetic ...

    4. Tantalum - In addition to hydrofluoric acid, fuming sulfuric acid, alkali and other chemical media, including hydrochloric acid, nitric acid and < 175℃ sulfuric acid can be used. 5. Platinum - can be used in all kinds of acids, bases, salts, but not aqua regia. Two, the choice of lining material

    Get Price
  • Electromagnetic Flow Meter, Magnetic Water Flow Meter ...

    Not for: alkali, hydrofluoric acid. Platinum. Suitable for: Almost all acid-base solutions (including fuming sulfuric acid and fuming nitric acid) Not for: aqua regia, ammonia salt. Tungsten carbide. Suitable for: pulp, sewage, mud, resistant to solid particles Not for: inorganic acids, organic acids and chlorides

    Get Price
  • Buy Gold Recovery Chemicals: Nitric Acid, Hydrochloric ...

    Nitric acid (aqua fortis and spirit of niter), commercial grade concentration 68% in water, removes base metals and is used in aqua regia. Hydrochloric acid 32% is used in e-waste recycling and is the main part of aqua regia. Aqua Regia is a gold recovery chemical solution. Sodium Bicarbonate (Soda) is a cleaning agent. If there is any dust or ...

    Get Price
  • Cleaning crucibles

    Cleaning crucibles : Hi. Does anybody have an easy way of cleaning the magnesium oxide out of crucibles after heating magnesium ribbon in them. I usually wash them in detergent, which leaves a stain, and then reuse them. I have been asked to find a better way of cleaning them.

    Get Price
  • Dichromic acid glass cleaner waste

    Dichromic acid glass cleaner waste: I use concentrated sulfuric acid and sodium dichromate in the glass cleaner I make. I have recently learned that sulfuric acid should not be put through the chemical waste pit that protects the waste water system. I reuse the cleaner until it is no longer active and changes pH. The residue from the glass ware is diluted with water when being

    Get Price
  • Mechanical Smart Electromagnetic Flowmeter

    However, if the acid contains oxidants (such as nitric acid, Fe +++, Cu ++), the corrosion is greatly reduced. Tantalum (Tan)Has excellent corrosion resistance, and the glass is very similar, in addition to hydrofluoric acid, fuming nitric acid, alkali, almost all chemical media (including hydrochloric acid, sulfuric acid and aqua regia) corrosion.

    Get Price
  • Electromagnetic Flowmeter Digital Magnetic Flowmeter-JXCT ...

    Electromagnetic Flowmeter Digital Magnetic Flowmeter Sewage, water, tap water, acid, alkali, salt and other strongly corrosive liquids, raw water, cooling water, paper pulp, mud, coal pulp, mineral pulp, syrup, corn steep liquor, fiber pulp, grain pulp, lime milk, hydrogen peroxide, sea water, beer , Wort, milk and various beverages and other conductive liquids and solid-liquid two-phase liquids.

    Get Price
  • Digital Water Flow Meter Price Electromagnetic Flowmeter ...

    1. It is the plastic with most stable chemical properties, and is resistant to boiled hydrochloric acid, sulphuric acid, nitric acid and aqua regia, and also strong alkali and varied organic solvents. 2. Wear resistant performance is lower than polyurethane rubber. 3. Negative pressure resistance is lower than poly neoprene.

    Get Price
  • Asmik water measuring device electromagnetic flowmeter ...

    Asmik water measuring device electromagnetic flowmeter, US 290 - 340 Piece, China, ASMIK, SPE-LDG-0068.Source from Hangzhou Asmik Sensors Technology Co., Ltd. on Alibaba.com.

    Get Price
  • A comparison of the extraction of mercury from sediments ...

    A study of the extraction of mercury from various sediments with hydrochloric-nitric acid, sulphuric-nitric acid and hydrofluoric acid-aqua regia mixtures is reported. The mercury in the extract is detected by using an automated cold-vapour atomic-absorption technique. Although greater extraction of mercury from se

    Get Price
  • Electromagnetic Flow Meter

    Integrated Electromagnetic Flow Meter : Nominal diameter: DN3-DN3000 Nominal pressure: 0.6-4.0MPA Accuracy: ± 0.5% of indicated value Lining material: polyurethane rubber chloroprene rubber polytetrafluoroethylene silicone lining Electrode form: standard type scraper type replaceable type Electrode material: 316L Haz alloy B Haz alloy C titanium tantalum platinum

    Get Price
  • Aqua Regia

    Aqua regia (Latin for 'Royal Water') is a solution of nitrohydrochloric acid. The traditional solution is comprised of a 3:1 mixture of hydrochloric acid and nitric acid, respectively. It is commonly used to remove noble metals such as gold, platinum and palladium from substrates, particularly in microfabrications and microelectronics labs.

    Get Price
  • Electromagnetic flow meter electrode - Just Measure it

    3. Corrosion resistance to oxidizing acids such as nitric acid at room temperature 4. Reducing acids such as hydrochloric acid and sulfuric acid are not applicable: Ta: 1. Has superior corrosion resistance similar to glass 2. Except for a few acids such as hydrofluoric acid, fuming sulfuric acid, most acid solutions are suitable 3.

    Get Price
  • MFE600-Intelligent-Electromagnetic-Flowmeter

    MFE600-Intelligent-Electromagnetic-Flowmeter - Read online for free. knowledge

    Get Price
  • Electromagnetic Flowmeter - Supmea

    Supmea electromagnetic flowmeters have been used throughout industries for more than 60 years. These meters are applicable for all conductive liquids, such as water, acids, alkalis, slurries, sewage and many others. Get quote and catalog, Contact us: 0086-15158063876

    Get Price
  • CHAPTER 13 WET DIGESTION METHODS - pg.gda.pl

    Chapter 13 227 The majority of wet digestion methods (total decomposition and strong attack) involve …

    Get Price
  • Aqua Regia - - Division of Research Safety

    Aqua Regia (Latin for “royal water”) is an acidic, corrosive, and oxidative mixture of three parts concentrated hydrochloric acid (HCl) and one part concentrated nitric acid (HNO3). It is called aqua regia because it is one of the few acid mixtures that can dissolve the “noble” metals: gold (Au), platinum (Pt), and palladium (Pd).

    Get Price
  • DN65 Caliber Waste Water Mechanical Acid Liquid Flow Meter

    However, if the acid contains oxidants (such as nitric acid, Fe +++, Cu ++), the corrosion is greatly reduced. Tantalum (Tan)Has excellent corrosion resistance, and the glass is very similar, in addition to hydrofluoric acid, fuming nitric acid, alkali, almost all chemical media (including hydrochloric acid, sulfuric acid and aqua regia) corrosion.

    Get Price
  • Electromagnetic Flowmeter Manufacturer Supplier - Hebei ...

    Product details: 1. LCD backlight display 2. Instantaneous flow, cumulative flow meter, flow bar graph, flow percentage 3. One-click query of net cumulative value, positive cumulative value, negative cumulative value, current conductivity equivalent 4. Multiple units can be switched (L, m³, Kg, t s, min, h) 5. 485 communication remote read data 6. Upgraded thickened high-strength flange ...

    Get Price
  • Decomposition procedure with aqua regia and hydrofluoric ...

    Analytica Chimica Acta, 237 (1990) 251-252 Elsevier Science Publishers B.V., Amsterdam Short Communication Decomposition procedure with aqua regia and hydrofluoric acid at room temperature for the spectrophotometric determination of phosphorus in rocks and minerals C.R.M. Rao and G.S. Reddi Geological Survey of India, Guindy, Madras-32 (India) (Received 30th March 1990) Abstract A rapid ...

    Get Price
  • A comparison of the extraction of mercury from sediments ...

    A study of the extraction of mercury from various sediments with hydrochloric-nitric acid, sulphuric-nitric acid and hydrofluoric acid-aqua regia mixtures is reported. The mercury in the extract is detected by using an automated cold-vapour atomic-absorption technique. Although greater extraction of mercury from se

    Get Price
  • Aqua Regia Synthesis Essay - sdprofes.cl

    Aqua regia Aqua regia is a very strong acid formed by the combination of concentrated nitric acid and concentrated hydrochloric acid, both of which are strong acids. As an exercise for students, try synthesizing PdCl2 from palladium metal with aqua regia. otherwise follow the standard protocol for cleaning of Teflon beaker as mentioned below: 1 ...

    Get Price
  • The 1 Best Nitric Acid Puns - Punstoppable ?

    Related Topics. Nitric acid: Nitric acid (HNO3), also known as aqua fortis (Latin for 'strong water') and spirit of niter, is a highly corrosive mineral acid.The pure compound is ... Red fuming nitric acid: Red fuming nitric acid (RFNA) is a storable oxidizer used as a rocket propellant.It consists of 84% nitric acid (HNO3), 13% dinitrogen tetroxide and ...

    Get Price
  • Magyn

    MAGYN -Intelligence Electromagnetic Flowmeter. YINUO MAGYN Serials Intelligence Electromagnetic Flowmeter General MAGYN Serials Intelligence Electromagnetic Flowmeter conducts measurement based on the principle of the Faraday Blecttximagnetic Induction Law. When conductive liquid flows in a magnetic field and incises the magnetic flux, Induced electromotive force E will be generrated in the ...

    Get Price
  • LUDWIG SCHNEIDER Electromagnetic Flowmeter

    Electromagnetic Flowmeter Model FE10 FE10 electromagnetic flowmeter is a high-precision, high-reliability flowmeter. It is used to measure the volume flow of conductive liquid and slurry in closed pipelines. It is widely used in steel, electric power, petroleum, chemical, coal, metallurgy,

    Get Price
  • Intelligent Electromagnetic Flowmeter Instruction Manual EN

    Has excellent corrosion resistance, very similar to glass, except hydrofluoric acid, oleum, alkali, and can withstand almost all chemical media (including boiling point hydrochloric acid, nitric acid and sulfuric acid and aqua regia below 150P) Note: in Not For non

    Get Price
  • How to choose the right electromagnetic flowmeter material ...

    How to choose the right electromagnetic flowmeter material. by:Sure 2020-06-28 ...

    Get Price
  • piranha solution vs aqua regia - ochocobrewing.com

    The piranha and aqua regia solutions are highly corrosive and can be explosive. Aqua Regia: This mixture of nitric acid and hydrochloric acid is sometimes used to dissolve nanomaterials, noble metals or as a gas cleaner. Do not dispose with organic solvents Only standard chemicals and cleanroom equipment/tools are required.

    Get Price
  • The 4 Most Dangerous Acids in the World - ThoughtCo

    Aqua Regia . Strong acids typically dissolve metals, but some metals are stable enough to resist the effects of acid. This is where aqua regia becomes useful. Aqua regia means 'royal water' because this mixture of hydrochloric and nitric acid can dissolve noble metals, such as gold and platinum.Neither acid …

    Get Price
  • Why does ammonia react with nitric acid ...

    The mark is tested by applying nitric acid, which dissolves the mark of any item that is not gold. If the mark remains, it is tested by applying aqua regia (nitric acid and hydrochloric acid). What happens when nitric acid is treated with gold? The two acidic testing solutions react with gold alloys by dissolving all or some of the metals ...

    Get Price
  • Catalogo Electromagnetic Flowmeter

    Catalogo Electromagnetic Flowmeter - Free download as PDF File (.pdf), Text File (.txt) or read online for free. ... It can resist corrosion from grease, various chloride salt and sub-chloride, oxidizing acid (including fuming vitriol, nitric acid), organic ... Long-term usage temperature of flow meter: -40C~+180C. boiling hydrochloric acid ...

    Get Price
  • How To Choose Flowmeter’s Material? - Flowmeter

    Has excellent corrosion resistance, and similar to glass, in addition to hydrofluoric acid, fuming nitric acid, alkali. It can resist the corrosion of almost all chemical medium (including hydrochloric acid, nitric acid, sulfuric acid under 150℃, and aqua regia…

    Get Price
  • Chemistry terms - larapedia.com

    Chemistry terms . Chemistry terms . The following texts are the property of their respective authors and we thank them for giving us the opportunity to share for free to students, teachers and users of the Web their texts will used only for illustrative educational and scientific purposes only.

    Get Price
  • Perrys-chemical-engineers-handbook-1999

    Perrys-chemical-engineers-handbook-1999 | ð ð»ñ ñ ðð²ð¸ñ ñ ñ ð½ð¾ð² ... Much of Bob Perry's work carries over into this edition and his influence is both recognized and remembered. .... enthalpy kcal/(gâ mol) kJ/kmol 4.184* E + 03 (mole basis) Btu/(lbâ mol) kJ/kmol 2.326 000 E + 00 Calorific value (volume Btu/U.S. gal MJ/m3 kJ/dm3 2.787 163 E ..... 2-114 2-37 Ammonium ...

    Get Price
  • - Division of Research Safety

    Nitric Acid (HNO 3) Nitric acid is supplied as concentrated acid (68-70%, 16M), fuming strength (>86%), and as anhydrous form (100%). It is a strong oxidizer even when fairly dilute and at room temperature. It oxidizes most organic compounds while it is reduced to nitrous fumes. Anhydrous nitric acid can form highly explosive mixtures with ...

    Get Price
  • Chemically Resistance of Tungsten

    Hydrochloric Acid Resistant to attack Sulfuric Acid Resistant to attack Nitric Acid Resistant to attack Aqua Regia - cold Resistant to attack Hydrofluoric Acid Resistant to attack Caustic Soda, Aqueous Solution Resistant to attack Ammonia to 700 °C Resistant to attack Mercury Mercury Vapor Resistant to attack Air Oxygen to 400 °C Resistant […]

    Get Price
  • Acid Flow Meter to Measure HNO3, HF 70% or Alkali

    Electromagnetic flow meters can be used as a kind of acid flow meter or alkali flow meter, not just limited to sewage flow meter, portable water flow meter or milk flowmeters. By choosing different kinds of magnetic meter wet parts material, the mag meter can take task to measure varies kind corrosive medium.

    Get Price
  • FE20 Series Electromagnetic Flowmeter - Kewill-auto

    FE20 Electromagnetic Flowmeter characteristic…disadvantages ... A material of stable chemical,can withstand boiling hydrochloric acid ,sulfuric acid,nitric acid and aqua regia ,strong alkali and various organic solvent,not withstand chlorine trifluoride,high temperature oxygen difluoride. ... sulfuric acid, hydrofluoric acid organic acid ...

    Get Price
  • WE PROVIDE NOT ONLY PRODUCTS BUT ALSO SOLUTIONS FOR CUSTOMER

    1. Hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid) 2. Chlorine dioxide, ferric chloride, hypochlorite, sodium cyanide, lead acetate, etc 3. Oxidizing acids such as nitric acid (including fuming nitric acid), aqua regia with temperature lower than 80 °C

    Get Price
  • Chemical resistance PVDF - Polyfluor

    Chemical resistance PVDF. PVDF is very suitable for applications that require an excellent chemical resistance,a high degree of purity and superior mechanical properties. PVDF is often used as a coating or protection cover in chemical industry applications. Note: The chemical resistance of each polymer is mainly determined by the chemical ...

    Get Price
  • An investigation of the dissolution of hafnium-free ...

    Hf-free Zr has good corrosion resistance in all mineral acids with exception of hydrofluoric acid, concentrated sulfuric and phosphoric acids, and aqua regia. The resistance of Zr to attack in concentrated nitric acid is excellent, with but negligible attack occurring in fuming nitric acid.

    Get Price
  • Nitric Acid in Ahmedabad - Krunal Acid Agency

    Nitric acid (HNO 3), also known as aqua fortis and spirit of nitre, is a highly corrosive and toxic strong acid that can cause severe burns.The synthesis of nitric acid was first recorded circa 800 AD by the Muslim alchemist Jabir ibn Hayyan. Colorless when pure, older samples tend to acquire a yellow cast due to the accumulation of oxides of nitrogen.

    Get Price
  • COYNE-1997 A Practical Guide To Materials

    COYNE-1997 a Practical Guide to Materials, - Free ebook download as PDF File (.pdf), Text File (.txt) or read book online for free.

    Get Price